Skip to content
Drainage Solutions for New Development vs. Retrofit Projects: What Changes and What Doesn’t

Drainage Solutions for New Development vs. Retrofit Projects: What Changes and What Doesn’t

New development and retrofit projects approach drainage with fundamentally different constraints, design considerations, and engineering priorities. New developments begin with a clean slate, allowing engineers to plan for continuous downward slopes and larger-diameter pipes. Retrofit projects, by contrast, must accommodate existing structures, limited space, and legacy infrastructure.

When selecting a drainage solution, engineers and architects must weigh numerous factors in determining whether traditional gravity-based drainage systems or vacuum-based systems offer the best fit for a project’s requirements.

The Vacuum vs. Gravity Series by Evac: an editorial series on vacuum drainage for commercial buildings

At a Glance

  • New builds can usually plan for the continuous slopes and larger pipes that gravity drainage needs; retrofits must work around the existing structure.
  • In retrofits, gravity drainage can mean cutting post-tensioned slabs or historic fabric, and may need ejector pits where existing sewer mains sit too high.
  • Vacuum drainage uses smaller pipes that can run horizontally, vertically or overhead, but it needs electrical power and space for a central vacuum station.
  • Vacuum toilets typically use 80–90% less water per flush than conventional gravity toilets.

The basic differences are:

  • Gravity Drainage Systems: Traditional gravity drainage systems use gravity to move wastewater and waste through sloped piping to a municipal main or other lower-elevation discharge point.
  • Vacuum Drainage Systems: Vacuum drainage systems utilize negative pressure to move waste and wastewater through a closed network of pipes. Unlike a gravity-based system, vacuum systems are not dependent on continuous downward slopes and can move waste around obstacles, up slopes and even vertically.

Vacuum drainage in this article means sanitary drainage from toilets and other fixtures, not siphonic roof drainage for rainwater, which is a different technology.

Perspective: New Development

Every building project has unique drainage requirements. For a straightforward new build, a conventional gravity system may be the most cost-effective solution, at least in the short term. However, when challenging terrain, structural limitations, or water-conservation goals add complexity, a vacuum system can provide greater design flexibility.

Gravity Drainage Requirements

  • Impact for architects. Gravity drainage systems require sufficient floor and/or ceiling voids to accommodate large-diameter pipes and continuous downward slopes, typically 1% to 2%. These requirements can require thicker slabs or stepped floor levels, potentially affecting floor-to-floor heights in multi-story buildings.
  • Impact for engineers. Gravity systems often require extensive below-slab trenching, deep pipe invert elevations, and carefully coordinated pumping when site conditions are challenging. These complications can include areas with shallow bedrock, high water tables, or flat terrain.
  • Cost and familiarity. Builders, architects and engineers tend to be more familiar with traditional gravity-based systems. Gravity systems often have a lower upfront cost, although vacuum-based systems can offer long-term savings in some projects.

Vacuum Drainage Requirements

  • Impact for architects. For new development projects, vacuum drainage systems can reduce deep core drilling and slab-to-slab height requirements because their smaller-diameter pipes can be routed flexibly through ceilings, walls or shallow floor tracks.
  • Impact for engineers. Vacuum-based plumbing systems require dedicated mechanical space for a central vacuum generator and control panel, as well as integration with vacuum-based fixtures like vacuum toilets.
  • Cost and use cases. Although vacuum plumbing systems may involve higher initial equipment costs, the investment can be worthwhile in high-rise buildings, high-occupancy venues, and sites with challenging terrain. Compared with conventional gravity systems, vacuum systems can deliver substantial water savings and sustainability benefits while reducing mechanical, electrical, and plumbing (MEP) coordination conflicts and disruptions.

Perspective: Retrofit and Adaptive Reuse

Historic renovations, heritage conversions or structural remodels create a different set of complications, with the existing physical structures dictating design.

Gravity Drainage Requirements

  • Impact for architects. Gravity drainage systems typically present significant challenges for architects. These can include cutting into post-tensioned slabs, thick historic masonry, or protected heritage fabric. These challenges need to be addressed when installing sloped, large-diameter piping, which can compromise structural integrity.
  • Impact for engineers. For engineers, gravity drainage systems in retrofit and adaptive reuse projects create conflicts when existing sewer mains sit too high relative to new fixture locations. These elevation conflicts may necessitate costly ejector pits or raising entire floor levels to achieve proper drainage.
  • Limitations. Relocating plumbing fixtures, such as toilets and sinks, away from existing vertical drainage stacks can be expensive and complex, often requiring raised floor platforms or other significant structural changes.

Vacuum Drainage Requirements

  • Impact for architects. Vacuum-based plumbing systems utilize smaller-diameter pipes which can be routed around and over obstacles, including vertically, or through existing ceiling voids, shaft spaces, or through minor core cuts.
  • Impact for engineers. Vacuum-based systems largely avoid invert elevation constraints because negative pressure pulls wastewater horizontally or even vertically to the central collection site.
  • Water and sustainability benefits. Typical water consumption is just 0.8–1.2 liters (about 0.2–0.3 gallons) per flush for vacuum toilets, compared to 4.8–6.0 liters (about 1.3–1.6 gallons) per flush for modern gravity toilets, and up to 13–26 liters (about 3.4–6.9 gallons) for older-model gravity toilets. Vacuum plumbing can help lower a renovation’s carbon footprint by reducing demolition, slab penetrations and new materials, and by cutting water use. The vacuum plant uses electricity, so the overall balance depends on the project.

Key Considerations

ConsiderationGravity DrainageVacuum Drainage
Pipe SizeLarge diameter, heavy loadSmall diameter; lightweight
Routing FlexibilityDownward gradient requiredCan run horizontally, vertically, or uphill
Slab & Void ImpactOften requires deep trenches or large ceiling voidsAccommodates shallow spaces and existing shafts
Retrofit ViabilityOften limited: slab cutting, risk to historic fabric, invert issuesOften high: can route around slabs, post-tensioned tendons and heritage walls
Power DependencyNone. Utilizes gravity.Requires electrical power for vacuum pumps

Whether planning a new development or renovating an existing building, choosing a drainage system involves balancing upfront costs, installation complexity, space requirements and long-term sustainability. Gravity drainage benefits from established design practices and typically lower initial equipment costs, but its dependence on sloped, large-diameter piping can increase excavation, structural coordination and renovation expenses.

Vacuum drainage offers an alternative that can simplify pipe routing, reduce slab penetrations and demolition, and accommodate challenging building configurations. Its water-efficiency benefits are particularly notable: vacuum toilets typically use approximately 0.8–1.2 liters per flush, compared with 4.8–6.0 liters for modern gravity toilets. These reductions can lower water demand and wastewater volumes while supporting broader sustainability goals.

Although vacuum systems require electrical power and dedicated equipment, their combination of design flexibility, reduced construction disruption, and potential long-term resource savings makes them worth evaluating for both new construction and adaptive reuse.

To learn more about Evac’s line of total vacuum solutions, contact us today!

Contact Evac Built Environment team

Planning a new build, renovation or conversion? Tell us a little about your project, and our Built Environment team will show you how vacuum plumbing can help you meet your design, space and sustainability goals.

Contact us

Search